Panasonic Corporation LabAlert Monitoring System Accessories - KIT, TEMP, RH, LABALERT - NTC-TRH-KIT
In Stock
$1,047.99
SKU NTC-TRH-KIT
Discount Code: Use code TAKE5 for 5% OFF Total Purchase
Free Shipping Orders Over $100
Questions? Speak with a specialist!
Chat with us!
Give us a call!
+1(415)683-7878
Email us!
support@graylinemedical.com
This item may require 5-7 days to ship out from our facility.
Product Information: KIT, TEMP, RH, LABALERT
Manufacturer Part # NTC-TRH-KIT
Description
- Accessories for LabAlert Monitoring System
- Gateway transmitter with 5V/2A power supply and 14' ethernet cable ; One required with each system, need customer to supply ethernet connection; Use with all equipment
- Gateway transmitter with 5V/2A power supply and 14' ethernet cable with Trigger Magnet (2 input) with alarm contact (Requires NTCPBUNIV or NTCLN2 temperature probes); One required with each system., need customer to supply ethernet connection, Built-in two sensor input and dry contact output, multii-level password support; Use with all equipment
- CO2 Sensor Probe (Requires NTC PS24V) Stand alone CO2 Sensor probe; Requires NTCPS24V and NTCANLG40xxPS transmitter; Use with C02 Incubators and other C02 controlled devised
- Earth magnet needed to trigger sensors to transmit; use with NTCGATEWAY, for all equipment
- LabAlert Power Supply, 24VDC
- Magnetic door switch, surface mount, plastic with wire leads ; 5/8" gap distance, 1 1/2" x 1/4" x 3/8" (Requires either NTC22xxPS or NTCUNIVZBPS); Use with Ultra-Low Freezers,-86°C; Lab Freezers,-30°C; Refrigerators; Refrigerator Freezer Combinations; Incubators, Heated and Refrigerated; Incubators, Temperature / Remote Contacts; Incubators,CO2/O2/RH/ Temperature
- Pressure sensor kit for LabAlert (Requires NTCANLG40xxPS transmitter); Includes pressure transducer and 24V power supply; Use with Clean Room Pressure monitoring
- Transmitter with 4 analogue 1-5V DC inputs for monitoring analogue signals; Approximately 200 ft. range; (2) Lithium batteries - lasts up to 10 years, Automatically joins network; Will store data for 1 week in case of power failure or internet outage on gateway/probe; Display +/- 1ºC Accuracy (+/- 0.5ºC when calibrated); Coated electronic circuit board ; Use with Incubators,CO2/O2/RH/ Temperature or other 0-5v or 4-20mA output signals
- Temperature probe for LN2 tank; Requires universal transmitter; Use with Cryogenic/ Vapor Phase, -160°C
- Transmitter for -40˚ to +60˚C; Quad input can use 1 to 4 sensors; Use with Lab Freezers,-30°C; Refrigerators; Refrigerator Freezer Combinations; Incubators, Heated and Refrigerated
- Temperature Probe -40˚C TO +60˚C use with Lab Freezers,-30°C; Refrigerators; Refrigerator Freezer Combinations; Incubators, Heated and Refrigerated;Incubators, Temperature/ Remote Contacts; Incubators,CO2/O2/RH/ Temperature
- Transmitter for -90 ˚to -40˚C ; Quad input can use 1 to 4 sensors; Use with Ultra-Low Freezers,-86°C
- Temperature probe for -90˚C to -40˚C for use with Ultra-Low Freezers,-86°C
- Transmitter with 1 x -40˚C to +60˚C temp input and one switch closure input / use with Incubators, Temperature/ Remote Contacts; Incubators,CO2/O2/RH/ Temperature
- Transmitter for -160˚ to +60˚ (2 input) with alarm contact ; For use with temperature ranges from -160˚ to +60˚
- Temperature probe for -160˚C to +60˚C (Requires universal transmitter NTCUNIVZBPS); use with Cryogenic/ Vapor Phase, -160°C
- Wireless room sensor with integrated temp/RH transmitter, Operating temperature of -40°C to 85°C ; use with Ambient/Room Humidity Temperature
- Vaccine simulation glass 10 ml bottle with NTC-PBHT temperature probe (Sensor + bottle solution) ; use with Refrigerators: Refrigerator Freezer Combinations
- Temperature Humidity Kit (Requires NTCANLG40xxPS transmitter); For use in chambers to measure temperature and humidity
HPIS Code | 220_40_140_0 |
Latex Free | Yes |